Fully-automated clinical chemistry analyzer Respons® 910

respons®910 is a compact and fully-automated bench top analyzer for maximum efficiency. During its development, special attention was paid to easy handling and optimized work flow thus leading to the ideal clinical chemistry system for many laboratories.

Versatile and Flexible

High on-board capacity of 30 different methods in mono- or twin-containers and 30 sample positions offers the necessary flexibility for everyday use. The integrated STAT port allows easy loading of emergency samples at any time. The wide range of high-quality clinical chemistry and immunoturbidimetric tests manufactured by DiaSys rounds off the respons®910 system.

Easy to Use

Ready-to-use reagents, adapter free one-grip loading of reagent containers, integrated bar code reader for sample and reagent as well as the intuitive software alleviates daily workload significantly.

Competitive and Unique

Minimized service and maintenance costs, low reagent consumption and high on board-stability of DiaSys system reagents in combination with highest result safety add up for a highly competitive system. Further features like LIS-connectivity, clot detection and crash sensor make respons®910 unique in its class.

Model: Respons 910
Manuf.: DiaSys Diagnostics
Country: Germany
Throughput: 150 tests/hour
Sample: Serum, plasma, whole blood, urine, CSF
Web: https://www.diasys-diagnostics.com

Brochure / Website

Features and Functions

System typeBench top clinical chemistry analyzer
Throughput150 tests/hour for mono-reagents; 100 tests/hour for 2 component reagents
Combined reagent/sample tray30 reagent positions plus 30 patient sample positions, easy removable tray for storage in refrigerator
Sample typesSerum, plasma, whole blood,urine, CSF
Sample volume2 – 30 μL
Reagent pipetting volumeReagent 1: 120 – 250 μL Reagent 2: 10 – 50 μL
STAT-analytics2 sample positions for loading of emergency samples at any time
Ion measurementEnzymatic tests for Cl, K, Na, Li
Bar code identificationAutomatic bar code scan for reagents and samples
Measuring principleColorimetry (Rate/End Point); Turbidimetric Immunoassay
CalibrationLinear, non-linear, multi-point
Sample tubes/cupsPrimary tubes of 5, 7 and 10 mL and sample cups
Reagent on-board capacity30 different methods in bar coded mono – or twin – containers for adapter-free one-grip loading
Reaction temperature37 ± 0.2 °C
Reaction unitTemperature controlled heated rotor with 105 disposable plastic cuvettes (37 ± 0.2 °C)
Photometry12 wavelengths: 340, 380, 405, 450, 480, 508, 546, 570, 600, 660, 700 and 800 nm (mono- and bichromatic)
Photometric linearity and resolution0 – 3.0 OD; resolution: 0.0001 OD
Water consumption< 1 liter per hour
LIS connectivityGiven
System interfaceAnalyzer – PC: USB connectivity bi-directional; CPU: Pentium IV or higher
Power source/power consumptionAC 110/220 V, 60/50 Hz; 300 VA excluding PC/printer/monitor
Dimensions60 cm (W) x 67 cm (D) x 60 cm (H)
WeightApproximately 60 kg